5-14
Sun Server X2-4 Service Manual • April 2013
▼
Install the Power Supply Backplane
Refer to
FIGURE 5-7
when completing the following procedure.
1. Unpack the replacement power supply backplane and place it on an antistatic
mat.
2. Hold the power supply backplane at the end of the power supply cage and
connect the AC cables to the AC connectors on the power supply backplane.
Ensure that each AC cable is connected to the appropriate connector. The AC cable
on the right must be connected to the AC connector on the right and the AC cable
on the left must be connected to the AC connector on the left.
3. Insert the power supply backplane into position by ensuring that the tabs on
the power board slide onto the hooks on the power supply cage (Step 1 in
FIGURE 5-7
).
4. Install the motherboard.
See
“Install the Motherboard” on page 5-20
. The motherboard installation
procedure involves reinserting and tightening the four bus bar screws that secure
the motherboard to the power supply backplane, as shown in Step 2 in
FIGURE 5-7
.
5. Replace the power supply cover and fasten it in place with the screw (Step 3 in
FIGURE 5-7
).
6. Reconnect the ribbon cable from the motherboard to the power supply
backplane.
7. Reinstall the air divider by sliding it into the chassis.
8. Reinstall the memory riser or filler panel closest to the air divider.
See
Section 4.1.8 “Removing and Installing Memory Risers, DIMMs, and Filler
Panels” on page 4-8
.
Содержание Fire X4470 M2
Страница 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Страница 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Страница 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Страница 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Страница 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Страница 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Страница 153: ...Appendix A Server Specifications A 3...
Страница 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Страница 156: ...B 2 Sun Server X2 4 Service Manual April 2013 B 1 BIOS Main Menu Selections FIGURE B 1 BIOS Main Menu...
Страница 158: ...B 4 Sun Server X2 4 Service Manual April 2013 FIGURE B 3 BIOS Advanced Menu CPU Configuration First Screen...
Страница 160: ...B 6 Sun Server X2 4 Service Manual April 2013 FIGURE B 6 BIOS Advanced Menu ACPI Configuration Screen...
Страница 161: ...Appendix B BIOS Setup Utility Menus B 7 FIGURE B 7 BIOS Advanced Menu AHCI Configuration Screen...
Страница 162: ...B 8 Sun Server X2 4 Service Manual April 2013 FIGURE B 8 BIOS Advanced Menu I O Virtualization Screen...
Страница 166: ...B 12 Sun Server X2 4 Service Manual April 2013 B 3 BIOS PCIPnP Menu Selections FIGURE B 15 BIOS PCIPnP Menu First Screen...
Страница 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Страница 168: ...B 14 Sun Server X2 4 Service Manual April 2013 B 4 BIOS Boot Menu Selections FIGURE B 17 BIOS Boot Menu...
Страница 170: ...B 16 Sun Server X2 4 Service Manual April 2013 B 5 BIOS Security Menu Selections FIGURE B 20 BIOS Security Menu...
Страница 171: ...Appendix B BIOS Setup Utility Menus B 17 B 6 BIOS IO MMIO Menu Selections FIGURE B 21 BIOS IO MMIO Menu...
Страница 172: ...B 18 Sun Server X2 4 Service Manual April 2013 FIGURE B 22 BIOS IO MMIO Menu IO MMIO Ration Configuration Screen...
Страница 173: ...Appendix B BIOS Setup Utility Menus B 19 B 7 BIOS Chipset Menu Selections FIGURE B 23 BIOS Chipset Menu...
Страница 174: ...B 20 Sun Server X2 4 Service Manual April 2013 FIGURE B 24 BIOS Chipset Menu South Bridge Configuration Screen...
Страница 175: ...Appendix B BIOS Setup Utility Menus B 21 B 8 BIOS Exit Menu Selections FIGURE B 25 BIOS Exit Menu...
Страница 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Страница 182: ...C 6 Sun Server X2 4 Service Manual April 2013...