Chapter 3
Servicing CRU Components That Do Not Require Server Power Off
3-3
3. On the disk drive filler panel you want to remove, push the release button to
open the latch.
4. Grasp the latch and pull the filler panel out of the drive slot.
Caution –
The latch is not an ejector. Do not bend it too far to the right. Doing so can
damage the latch.
Caution –
Whenever you remove a disk drive filler panel, you should replace it with
another filler panel or a disk drive; otherwise, the server might overheat due to
improper airflow.
▼
Remove a Disk Drive
Refer to
FIGURE 3-2
when completing the following procedure.
1. Attach an antistatic wrist strap.
See
Section 2.3 “Performing Electrostatic Discharge and Static Prevention
Measures” on page 2-3
.
2. Identify the disk drive you want to remove.
The amber Service Action Required LED on the drive might be lit.
See
Section 3.1.1 “Disk Drive Status LED Reference” on page 3-1
.
3. Determine whether you can replace the disk drive using the hot-plug procedure
or whether you need to power off the server and use the cold-swap procedure.
A cold-swap is required if the disk drive:
■
Contains the operating system, and the operating system is not mirrored on
another drive
■
Cannot be logically isolated from the online operations of the server
4. Do one of the following:
■
To cold-swap the drive, power off the server. Complete one of the procedures
described in
Section 2.6 “Powering Off the Server” on page 2-6
.
■
To hot-plug the drive, take the drive offline. This removes the logical software
links to the drive and prevents any applications from accessing it. For
information on how to take a disk drive offline, refer to the
Sun Disk
Management Overview
at
docs.oracle.com/cd/E19591-01/820-6350/index.html
.
Содержание Fire X4470 M2
Страница 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Страница 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Страница 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Страница 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Страница 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Страница 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Страница 153: ...Appendix A Server Specifications A 3...
Страница 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Страница 156: ...B 2 Sun Server X2 4 Service Manual April 2013 B 1 BIOS Main Menu Selections FIGURE B 1 BIOS Main Menu...
Страница 158: ...B 4 Sun Server X2 4 Service Manual April 2013 FIGURE B 3 BIOS Advanced Menu CPU Configuration First Screen...
Страница 160: ...B 6 Sun Server X2 4 Service Manual April 2013 FIGURE B 6 BIOS Advanced Menu ACPI Configuration Screen...
Страница 161: ...Appendix B BIOS Setup Utility Menus B 7 FIGURE B 7 BIOS Advanced Menu AHCI Configuration Screen...
Страница 162: ...B 8 Sun Server X2 4 Service Manual April 2013 FIGURE B 8 BIOS Advanced Menu I O Virtualization Screen...
Страница 166: ...B 12 Sun Server X2 4 Service Manual April 2013 B 3 BIOS PCIPnP Menu Selections FIGURE B 15 BIOS PCIPnP Menu First Screen...
Страница 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Страница 168: ...B 14 Sun Server X2 4 Service Manual April 2013 B 4 BIOS Boot Menu Selections FIGURE B 17 BIOS Boot Menu...
Страница 170: ...B 16 Sun Server X2 4 Service Manual April 2013 B 5 BIOS Security Menu Selections FIGURE B 20 BIOS Security Menu...
Страница 171: ...Appendix B BIOS Setup Utility Menus B 17 B 6 BIOS IO MMIO Menu Selections FIGURE B 21 BIOS IO MMIO Menu...
Страница 172: ...B 18 Sun Server X2 4 Service Manual April 2013 FIGURE B 22 BIOS IO MMIO Menu IO MMIO Ration Configuration Screen...
Страница 173: ...Appendix B BIOS Setup Utility Menus B 19 B 7 BIOS Chipset Menu Selections FIGURE B 23 BIOS Chipset Menu...
Страница 174: ...B 20 Sun Server X2 4 Service Manual April 2013 FIGURE B 24 BIOS Chipset Menu South Bridge Configuration Screen...
Страница 175: ...Appendix B BIOS Setup Utility Menus B 21 B 8 BIOS Exit Menu Selections FIGURE B 25 BIOS Exit Menu...
Страница 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Страница 182: ...C 6 Sun Server X2 4 Service Manual April 2013...