4-10
Sun Server X2-4 Service Manual • April 2013
■
If the memory riser Service Action Required LED is off: all DIMMs on this riser
are operating properly.
■
If the memory riser Service Action Required LED is on (amber): one or more of
the DIMMs installed on this riser is faulty or misconfigured.
Note –
Located above the Fault Remind button is the Fault Remind button Power
LED. When the Fault Remind button is pressed, the Power LED illuminates (green)
to indicate that the remind circuitry is working correctly.
FIGURE 4-3
Fault Remind Button on the Air Divider
3. Lift the memory riser that has its Service Action Required LED lit straight up to
remove the memory riser from the memory module socket (
FIGURE 4-4
).
Содержание Fire X4470 M2
Страница 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Страница 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Страница 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Страница 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Страница 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Страница 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Страница 153: ...Appendix A Server Specifications A 3...
Страница 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Страница 156: ...B 2 Sun Server X2 4 Service Manual April 2013 B 1 BIOS Main Menu Selections FIGURE B 1 BIOS Main Menu...
Страница 158: ...B 4 Sun Server X2 4 Service Manual April 2013 FIGURE B 3 BIOS Advanced Menu CPU Configuration First Screen...
Страница 160: ...B 6 Sun Server X2 4 Service Manual April 2013 FIGURE B 6 BIOS Advanced Menu ACPI Configuration Screen...
Страница 161: ...Appendix B BIOS Setup Utility Menus B 7 FIGURE B 7 BIOS Advanced Menu AHCI Configuration Screen...
Страница 162: ...B 8 Sun Server X2 4 Service Manual April 2013 FIGURE B 8 BIOS Advanced Menu I O Virtualization Screen...
Страница 166: ...B 12 Sun Server X2 4 Service Manual April 2013 B 3 BIOS PCIPnP Menu Selections FIGURE B 15 BIOS PCIPnP Menu First Screen...
Страница 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Страница 168: ...B 14 Sun Server X2 4 Service Manual April 2013 B 4 BIOS Boot Menu Selections FIGURE B 17 BIOS Boot Menu...
Страница 170: ...B 16 Sun Server X2 4 Service Manual April 2013 B 5 BIOS Security Menu Selections FIGURE B 20 BIOS Security Menu...
Страница 171: ...Appendix B BIOS Setup Utility Menus B 17 B 6 BIOS IO MMIO Menu Selections FIGURE B 21 BIOS IO MMIO Menu...
Страница 172: ...B 18 Sun Server X2 4 Service Manual April 2013 FIGURE B 22 BIOS IO MMIO Menu IO MMIO Ration Configuration Screen...
Страница 173: ...Appendix B BIOS Setup Utility Menus B 19 B 7 BIOS Chipset Menu Selections FIGURE B 23 BIOS Chipset Menu...
Страница 174: ...B 20 Sun Server X2 4 Service Manual April 2013 FIGURE B 24 BIOS Chipset Menu South Bridge Configuration Screen...
Страница 175: ...Appendix B BIOS Setup Utility Menus B 21 B 8 BIOS Exit Menu Selections FIGURE B 25 BIOS Exit Menu...
Страница 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Страница 182: ...C 6 Sun Server X2 4 Service Manual April 2013...