8-6
Sun Server X2-4 Service Manual • April 2013
3. Use a remote serial terminal or console running terminal emulation software to
access the Preboot Menu remotely.
Note –
You cannot use an SSH, or a remote KVMS session to access the Preboot
Menu remotely.
▼
Access the Preboot Menu
1. Ensure that the requirements in
Section 8.3.1.1 “Prerequisites for Accessing the
Preboot Menu” on page 8-5
are met.
2. Reset Oracle ILOM.
For example:
■
From the server SP ILOM, enter the command:
->
reset /SP
ILOM reboots and messages begin scrolling on the screen.
3. To interrupt the ILOM boot process, perform one of the following actions when
the SP is resetting:
■
Press and hold the Locate button on the server front panel, until the Preboot
Menu appears.
Or
■
Type in
xyzzy
when you see the message:
Booting linux in
n
seconds...
Note –
You cannot interrupt the Oracle ILOM boot process by typing
xyzzy
until
you have configured the settings as described in
“Edit Preboot Menu for Remote
Serial Access” on page 8-7
.
The Oracle ILOM Preboot Menu appears.
Booting linux in 10 seconds...
ILOM Pre-boot Menu
------------------
Type "h" and [Enter] for a list of commands, or "?" [Enter] for
command-line key bindings. Type "h cmd" for summary of 'cmd'
command.
Warning: SP will warm-reset after 300 seconds of idle time.
Содержание Fire X4470 M2
Страница 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Страница 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Страница 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Страница 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Страница 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Страница 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Страница 153: ...Appendix A Server Specifications A 3...
Страница 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Страница 156: ...B 2 Sun Server X2 4 Service Manual April 2013 B 1 BIOS Main Menu Selections FIGURE B 1 BIOS Main Menu...
Страница 158: ...B 4 Sun Server X2 4 Service Manual April 2013 FIGURE B 3 BIOS Advanced Menu CPU Configuration First Screen...
Страница 160: ...B 6 Sun Server X2 4 Service Manual April 2013 FIGURE B 6 BIOS Advanced Menu ACPI Configuration Screen...
Страница 161: ...Appendix B BIOS Setup Utility Menus B 7 FIGURE B 7 BIOS Advanced Menu AHCI Configuration Screen...
Страница 162: ...B 8 Sun Server X2 4 Service Manual April 2013 FIGURE B 8 BIOS Advanced Menu I O Virtualization Screen...
Страница 166: ...B 12 Sun Server X2 4 Service Manual April 2013 B 3 BIOS PCIPnP Menu Selections FIGURE B 15 BIOS PCIPnP Menu First Screen...
Страница 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Страница 168: ...B 14 Sun Server X2 4 Service Manual April 2013 B 4 BIOS Boot Menu Selections FIGURE B 17 BIOS Boot Menu...
Страница 170: ...B 16 Sun Server X2 4 Service Manual April 2013 B 5 BIOS Security Menu Selections FIGURE B 20 BIOS Security Menu...
Страница 171: ...Appendix B BIOS Setup Utility Menus B 17 B 6 BIOS IO MMIO Menu Selections FIGURE B 21 BIOS IO MMIO Menu...
Страница 172: ...B 18 Sun Server X2 4 Service Manual April 2013 FIGURE B 22 BIOS IO MMIO Menu IO MMIO Ration Configuration Screen...
Страница 173: ...Appendix B BIOS Setup Utility Menus B 19 B 7 BIOS Chipset Menu Selections FIGURE B 23 BIOS Chipset Menu...
Страница 174: ...B 20 Sun Server X2 4 Service Manual April 2013 FIGURE B 24 BIOS Chipset Menu South Bridge Configuration Screen...
Страница 175: ...Appendix B BIOS Setup Utility Menus B 21 B 8 BIOS Exit Menu Selections FIGURE B 25 BIOS Exit Menu...
Страница 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Страница 182: ...C 6 Sun Server X2 4 Service Manual April 2013...