Chapter 5
Servicing FRU Components
5-13
2. Pull both power supplies at least part way out of the chassis, to disconnect them
from the power supply backplane.
See
“Remove a Power Supply” on page 3-13
.
3. Remove the memory riser or filler panel closest to the air divider.
See
Section 4.1.8 “Removing and Installing Memory Risers, DIMMs, and Filler
Panels” on page 4-8
.
4. Remove the air divider by pulling it up and out of the chassis.
5. Remove the ribbon cable connecting the power supply backplane to the
motherboard.
6. Remove the screw holding the power supply cover in place and remove the
power supply cover (Step 1 in
FIGURE 5-6
).
7. Remove the motherboard.
See
“Remove the Motherboard” on page 5-19
. The motherboard removal
procedure involves removing the four bus bar screws that secure the motherboard
to the power supply backplane, as shown in Step 2 in
FIGURE 5-6
.
8. Disconnect the AC cables from power supply backplane.
9. Lift the power supply backplane out of the chassis (Step 3 in
FIGURE 5-6
).
FIGURE 5-6
Removing Power Supply Backplane
Содержание Fire X4470 M2
Страница 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Страница 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Страница 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Страница 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Страница 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Страница 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Страница 153: ...Appendix A Server Specifications A 3...
Страница 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Страница 156: ...B 2 Sun Server X2 4 Service Manual April 2013 B 1 BIOS Main Menu Selections FIGURE B 1 BIOS Main Menu...
Страница 158: ...B 4 Sun Server X2 4 Service Manual April 2013 FIGURE B 3 BIOS Advanced Menu CPU Configuration First Screen...
Страница 160: ...B 6 Sun Server X2 4 Service Manual April 2013 FIGURE B 6 BIOS Advanced Menu ACPI Configuration Screen...
Страница 161: ...Appendix B BIOS Setup Utility Menus B 7 FIGURE B 7 BIOS Advanced Menu AHCI Configuration Screen...
Страница 162: ...B 8 Sun Server X2 4 Service Manual April 2013 FIGURE B 8 BIOS Advanced Menu I O Virtualization Screen...
Страница 166: ...B 12 Sun Server X2 4 Service Manual April 2013 B 3 BIOS PCIPnP Menu Selections FIGURE B 15 BIOS PCIPnP Menu First Screen...
Страница 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Страница 168: ...B 14 Sun Server X2 4 Service Manual April 2013 B 4 BIOS Boot Menu Selections FIGURE B 17 BIOS Boot Menu...
Страница 170: ...B 16 Sun Server X2 4 Service Manual April 2013 B 5 BIOS Security Menu Selections FIGURE B 20 BIOS Security Menu...
Страница 171: ...Appendix B BIOS Setup Utility Menus B 17 B 6 BIOS IO MMIO Menu Selections FIGURE B 21 BIOS IO MMIO Menu...
Страница 172: ...B 18 Sun Server X2 4 Service Manual April 2013 FIGURE B 22 BIOS IO MMIO Menu IO MMIO Ration Configuration Screen...
Страница 173: ...Appendix B BIOS Setup Utility Menus B 19 B 7 BIOS Chipset Menu Selections FIGURE B 23 BIOS Chipset Menu...
Страница 174: ...B 20 Sun Server X2 4 Service Manual April 2013 FIGURE B 24 BIOS Chipset Menu South Bridge Configuration Screen...
Страница 175: ...Appendix B BIOS Setup Utility Menus B 21 B 8 BIOS Exit Menu Selections FIGURE B 25 BIOS Exit Menu...
Страница 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Страница 182: ...C 6 Sun Server X2 4 Service Manual April 2013...