98
7-3
6-2
Power Clamp
* = Factory adjusted mode
Trouble shooting
Code C14
Balancer recalibration by the user.
If several measuring runs are necessary to balance
a wheel because balance weight size and position
have to be readjusted repeatedly, this is often due to
insuffi cient measurement accuracy.
—
Balance a wheel, setting the type as NORMAL,
with less than 5 grams per plane.
—
Check in “
fi ne
” mode.
—
Go into code C14.
“CAL 1” appears and the machine beeps.
—
Perform the wheel measuring run.
At the end the display shows “CAL 2”.
—
Screw on the User Calibration Weight, as shown
in
Figure 6-2
.
—
Perform the wheel measuring run.
At the end the display appears as shown in
Figure 7-3
to indicate that calibration was performed
correctly.
Note
: Any error (by the operator) closes the program.
Error codes are listed in Section 7.1.2.
Code C21
This code provides information about the program
version and the balancer model name
—
Go into code C21.
Information about the software version appears.
—
Press the “
-
” key to view the Kernel version.
The information is visible for as long as the key is
pressed.
—
Press the “
+
” key or the “
FINE
” key to view the
balancer model.
Note
: The information is visible for as long as the
key is pressed.