D-2
SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
Could Not Connect to XSCF Through the Serial Port
■
Check the connection between the terminal software and the serial port.
■
Check the settings of the terminal software (baud rate is set to 9600 bps, delay is
set to 0, etc.). For information about the settings, see "Connecting to XSCF via the
serial port" in
Chapter 3
.
Could Not Connect Using Telnet to XSCF via the XSCF-LAN
■
Check the LAN cable connection between the XSCF terminal and the server.
■
Check the connection between the terminal software and the telnet port.
■
Use the
shownetwork
(8) command to check whether the setting for the XSCF-
LAN is enabled.
■
Use the
showtelnet
(8) command to check whether the setting for telnet is
enabled.
■
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed its
maximum number. For information about the maximum number, see
Chapter 2
and
Chapter 3
.
■
If necessary, use the console on the personal computer that is directly connected
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings by using the
shownetwork
(8) command.
Could Not Connect Using SSH to XSCF via the XSCF-LAN
■
Check the LAN cable connection between the XSCF terminal and the server.
■
Use the
shownetwork
(8) command to check whether the setting for the XSCF-
LAN is enabled.
■
Use the
showssh
(8) command to check whether the setting for SSH is enabled.
■
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed limit.
For information about the limitation, see
Chapter 3
.
■
If necessary, use the console on the personal computer that is directly connected
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings using the
shownetwork
(8) command.
■
Check whether the host key has the correct setting. During XSCF Unit
replacement, the host key setting is restored to the preset key setting of XSCF.
■
Check whether the client software has the correct settings.
Содержание Sun SPARC Enterprise M3000
Страница 4: ......
Страница 52: ...1 26 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 252: ...4 32 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 272: ...5 20 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 318: ...9 4 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 FIGURE 9 2 Example of the Tree Frame ...
Страница 348: ...A 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 366: ...C 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 397: ...Index 5 error messages 9 28 starting 9 5 XSCF LAN firewall 3 5 function 3 5 port number 3 5 serial connection 3 16 ...
Страница 398: ...Index 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...