2-132
SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
3. Use the
showdomainmode
(8) command to confirm the initial hardware
diagnostic level.
Enabling or Disabling the Host Watchdog Function and the Break Signal
Suppression
■
Command operation
1. Use the
showdomainmode
(8) command to display the host watchdog and break
signal suppression setting.
2. Use the
setdomainmode
(8) command to specify host watchdog and break
signal suppression.
<Example> Specify the maximum initial hardware diagnostic level for domain ID 0.
XSCF>
setdomainmode -d 0 -m diag=max
Diagnostic Level :min -> max
Secure Mode
:off
-> -
Autoboot
:on
-> -
CPU Mode
:auto
-> -
The specified modes will be changed.
Continue? [y|n]:
y
configured.
Diagnostic Level :max
Secure Mode
:off (host watchdog: unavailable Break-signal:receive)
Autoboot
:on (autoboot:on)
CPU Mode
:auto
<Example> Display the initial hardware diagnostic levels of domain
ID 0.
XSCF>
showdomainmode -d 0
Host-ID
:0f010f10
Diagnostic Level :max
Secure Mode :off
Autoboot
:on
CPU Mode
:auto
<Example> Display the setting for domain ID 0.
XSCF>
showdomainmode -d 0
Host-ID
:0f010f10
Diagnostic Level :max
Secure Mode :off
Autoboot
:on
CPU Mode
:auto
Содержание Sun SPARC Enterprise M3000
Страница 4: ......
Страница 52: ...1 26 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 252: ...4 32 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 272: ...5 20 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 318: ...9 4 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 FIGURE 9 2 Example of the Tree Frame ...
Страница 348: ...A 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 366: ...C 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 397: ...Index 5 error messages 9 28 starting 9 5 XSCF LAN firewall 3 5 function 3 5 port number 3 5 serial connection 3 16 ...
Страница 398: ...Index 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...