Chapter 8
Upgrade of XSCF Firmware and Maintenance
8-15
Note –
The display might be different according to XCP version and system
configuration.
At this time, the XSCF will reset and the XSCF session will disconnect, so
please connect the XSCF again. Only the application of the XSCF firmware is
completed.
Note –
The work described below applies to a system with redundant XSCF Units.
i) Perform the firmware update in order, beginning with the standby side and then
the active side automatically. After the update on the standby side is completed, the
active and standby sides are switched. At this time, the XSCF reset is done and the
XSCF session is disconnected.
ii) Re-connect the XSCF and log in again.
iii) XSCF firmware update is completed.
iv) When the firmware update completes, the active and the standby states of the
XSCF unit have become the opposite of original state. For instance, if the firmware
update is executed on XSCFU#0, when completing the command, XSCFU#1 would
become the active side. To switch the XSCF, execute the
switchscf
(8) command.
To confirm the switching between XSCFs, execute the
showhardconf
(8) command.
<Example>
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states. Continue? [y|n] :y
d. To confirm that the XSCF firmware update has finished, use the
showlogs
(8)
command with the monitor option. Confirm no abnormality is found during
the update. If the "XCP update has been completed" message is displayed in
each XSCF Unit, the firmware update has completed.
4. To complete the update of the OpenBoot PROM firmware, restart the domain.
5. Confirm that the version of the system firmware that is running is that of the
firmware applied at the XSCF Shell command line by using the
version(8)
command.
XSCF>
showlogs monitor
:
Jun 20 07:25:48 FF1-1-0 monitor_msg: SCF:XCP update has been completed (XCP
version=1082)
Содержание Sun SPARC Enterprise M3000
Страница 4: ......
Страница 52: ...1 26 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 252: ...4 32 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 272: ...5 20 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 318: ...9 4 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 FIGURE 9 2 Example of the Tree Frame ...
Страница 348: ...A 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 366: ...C 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 397: ...Index 5 error messages 9 28 starting 9 5 XSCF LAN firewall 3 5 function 3 5 port number 3 5 serial connection 3 16 ...
Страница 398: ...Index 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...