Chapter 4
Operation of the Server
4-17
Also, even if a system abnormality (like a fan or temperature abnormality) is
detected while the Solaris OS is being booted, or the system is running in single user
mode, there may be cases where the power cannot be turned off. (A Solaris OS
shutdown is not executed.) In such cases, immediately perform the procedure above.
4.4.5
Sending a Domain Panic Request
■
Command operation
1. Use the
showdomainstatus
(8) command to check the power status of the
domain to which a panic instruction is to be issued.
2. Use the
reset
(8) command to issue a panic instruction to the specified domain.
XSCF>
showdomainstatus -a
DID
Domain Status
00
Running
01
Running
02
Running
03
Running
<Example> Issue a panic instruction to the specified domain.
XSCF>
reset -d 0 panic
DomainID to panic:00
Continue? [y|n] :
y
00 :Panicked
*Note*
This command only issues the instruction to reset.
The result of the instruction can be checked by the
"showlogs power".
Содержание Sun SPARC Enterprise M3000
Страница 4: ......
Страница 52: ...1 26 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 252: ...4 32 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 272: ...5 20 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 318: ...9 4 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 FIGURE 9 2 Example of the Tree Frame ...
Страница 348: ...A 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 366: ...C 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Страница 397: ...Index 5 error messages 9 28 starting 9 5 XSCF LAN firewall 3 5 function 3 5 port number 3 5 serial connection 3 16 ...
Страница 398: ...Index 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...