Chapter 4
Operation of the Server
4-13
Note –
Only the domains that are able to be powered on are displayed.
4.4.2
System Power Off
■
Command operation
1. Use the
showdomainstatus
(8) command to check the power status of the
system.
2. Use the
poweroff
(8) command to turn off power to all domains.
XSCF>
poweron -a
DomainIDs to power on:00,01,02,03
Continue? [y|n] :
y
00 :Not powering on: The power supply has already been turned on.
01 :Powering on
02 :Powering on
03 :Powering on
*Note*
This command only issues the instruction to power-on.
The result of the instruction can be checked by the
"showlogs power".
XSCF>
showdomainstatus -a
DID
Domain Status
00
Running
01
Running
02
Running
03
Running