98
Serial Parallel Controller User’s Guide—February 1993
E
The test options are changed by modifying the
.usertest
file. To change
the test options:
1. As superuser, type
cd /usr/diag/sundiag
and press Return.
2. Use
vi
or another editor of your choice to change the
.usertest
file in
the
/usr/diag/sundiag
directory.
Each line in the
.usertest
file is in the following format:
sundiag test label, test name, command-line arguments
You can replace sundiag test label with whatever you want to be displayed on
the Sundiag control panel. Use
spiftest
for the test name. Refer to the
table earlier in this appendix and the Sundiag User’s Guide for all the available
command line arguments.
6. Your options are xonoff for Xon/Xoff, rtscts for hardware flow control, and both for xonoff and rtscts.
7. The selectable patterns are Hex. 5 for a 5 pattern,
Hex. a
for an A pattern, and
r
for a random pattern.