Sundiag
97
E
The Serial Parallel Controller tests appear under "USER TESTS" in the Sundiag
control panel. To run a test, with the mouse,
click
on the box next to one of the
ten tests listed above. Then
click
on the Sundiag start button.
Test Options
The Sundiag Serial Parallel Controller tests, except the Printer test, allow you
to change test options. The test options are shown in the following table.
Note – If you are running pre-2.0 Sundiag, do not enable the options in the
Options Window. If you do so, Sundiag will either fail or not recognize the
enabled option(s).
Table E-1
Test Options
Options
Default
Values
Description
D
any
See
footnote
1
1. Your options are sb1 (
/dev/ttyz00 - 07
), sb2 (
/dev/ttyz08 - 0F
), sb3 (
/dev/ttyz10 - 17
), and any
(
/dev/ttyz00 - 17
). For example, the sb1 option enables the eight serial ports on the first installed card
and the any (default) option enables the eight serial ports on any cards installed in SBus slots.
Specifies the device name.
T
1
See
footnote
2
2. Your options are 1 for Internal Loopback test, 2 for Printer test, 4 for 96-pin Loopback test, 8 for
DB-25 Loopback test, 16 for Echo
tty
test, or the sum of any combination.
Specifies the subtest name.
B
9600
110 -
38400
3
3. The selectable baud rates are 110, 300, 600, 1200, 2400, 4800, 9600, 19200, and 38400.
Specifies the baud rate.
C
8
5 - 8
Specifies the character length.
S
1
1, 2
4
4. Your options are 1 for 1 stop bit and 2 for 2 stop bits.
Specifies the number of stop bits.
P
0
0 - 2
5
5. Your options are none for no parity, even for even parity, and odd for odd parity.
Specifies parity.
F
rtscts
See
footnote
6
Specifies the flow control protocol.
I
A
5, A, r
7
Specifies the data for the loopback
tests.