Page 46
6-6
#7040748 - Revision A - September, 2016
Troubleshooting Guides
MODEL UW-24
MODEL UW-24
Wine Storage Error Code Troubleshooting Guide Instructions
Error Codes indicate problems logged by specific components. If error codes are logged, they appear before tem-
perature readings while in Diagnostic Mode and they can be toggled through with the temperature readings.
1.
With the unit ON, initiate Diagnostic Mode by pressing and holding either COLDER key, then press the POWER
key, then release both keys.
2.
Check for Error Codes on the display, making sure to toggle through all possible readings by pressing either
COLDER key. (See Error Code Table Below)
3.
If Error Codes appear, reference the Error Code Troubleshooting Guide on the next page.
a.
The left column of the Error Code Troubleshooting Guide lists the error codes.
b.
The right column of the Error Code Troubleshooting Guide explains what tests and/or corrective actions to
perform.
NOTE:
If error codes are observed, the SERVICE indicator appears constant when Diagnostic Mode ends, indicat-
ing error codes are logged. To clear this and the error codes from the software memory, the problem must be cor-
rected and the unit must be ON; then press and hold the ALARM key for 15 seconds. The control emits a quick
“beep” when the SERVICE indicator and error codes are cleared.
WINE STORAGE ERROR CODE TABLE
CODE INDICATION
05
Upper Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06
Upper Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07
Lower Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08
Lower Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
10
Upper Cabinet Warm Temperature alarm
11
Upper Cabinet Cold Temperature alarm
12
Lower Cabinet Warm Temperature alarm
13
Lower Cabinet Cold Temperature alarm
15
Sealed System Fault (evap temperature cannot drop 5° in 5 minutes, 3 consecutive valve activations)
Wine Storage Thermistor Location Codes
THERMISTOR LOCATION
CODE
Upper Evaporator
UE
Lower Evaporator
LE
Upper Compartment
UP
Lower Compartment
LO
MODEL ICB424