Page 38
5-10
#7040748 - Revision A - September, 2016
Component Removal
MODEL UW-24
MODEL UW-24
Condenser Fan Assembly Removal
The condenser fan motor is secured to the condenser
bracket with screws. The bracket is secured to the unit
tray by screws passing up from under the unit tray into
threaded stand-offs.
To access the condenser fan assembly, the unit needs
to be pulled from its installation.
NOTE:
If removing a unit from its installation, a coun-
tertop bracket may have been used to make a solid
installation. This countertop bracket mounting screws
need to be extracted.
After pulling unit from its installation (See Figure 5-19):
1.
Remove access panel from bottom back of unit.
2.
Disconnect fan motor electrical leads.
3.
Extract ground screw.
4.
Lean unit toward side, and extract bracket mounting
screws, then lift condenser fan assembly from unit.
Figure 5-19. Condenser Fan Assembly
Screws
Grounding Screw
Condenser
Fan Assembly