Page 39
5-11
#7040748 - Revision A - September, 2016
MODEL UW-24
MODEL UW-24
Component Removal
Figure 5-20. Unit Tray Component Access
Loosen Screws
on this side
Remove Screws
on this side
SEALED SYSTEM COMPONENTS
The sealed system contains R134a. To access any of
the sealed system components the unit will need to be
removed from the installation and the cabinet seperat-
ed. When servicing the sealed system, the refrigerant
valve assembly (includes filter-drier) MUST be replaced.
NOTE:
If removing a unit from its installation, a coun-
tertop bracket may have been used to make a solid
installation. This countertop bracket mounting screws
need to be extracted.
Separating Unit Cabinet
With unit out of installation (See Figure 5-20):
1.
Remove access panel from bottom back on unit.
2.
Extract screws securing unit tray to cabinet on the
left side, and loosen screws on right side.
3.
Separate cabinet from unit tray by leaning cabinet
to the right, then insert a spacer between cabinet
and unit tray (a 2x4 works well).
Heat Exchanger
The heat exchangers are no longer available as sepa-
rate components. They are now available only as
assemblies with the proper evaporator.