Page 16
2-13
#7040748 - Revision A - September, 2016
MODEL UW-24
MODEL UW-24
Electronic Control System
Figure 2-21. Cold Temperature Alarm, SERVICE Flashing
Figure 2-22. Cold Temperature Alarm with ALARM Feature Enabled,
SERVICE and ALARM Flashing with Audible Alarm Beeping
BEEP! BEEP! BEEP!
Figure 2-23. Clear Cold Temperature Alarm, Press POWER Key to Off, Then ON
Cold Temperature Alarm
A cold temperature alarm can occur if either wine storage compartment remains below 40°F too long, in conjunction
with several consecutive maximum run-time cycles. A cold temperature alarm situation will cause the SERVICE indi-
cator to flash (See Figure 2-21), and an appropriate error code to be logged; power to the compressor and condens-
er fan is also cut. If the temperature alarm feature has been enabled by pressing the ALARM on the control panel,
the ALARM indicator will also flash, and the audible alarm will beep. (See Figure 2-22)
NOTE:
To clear the cold temperature alarm, the problem must be corrected, then press the POWER key to switch
the unit OFF, then press it again to switch the unit back ON. (See Figure 2-23) Also see Clearing Error Codes, later
in this section.