ANTI LEGIONNAIRES' DISEASE PROGRAM
The anti-Legionnaires’ disease (pasteurisation) program of the boiler can only be used when the boiler is set as
an “indirect” boiler configuration or a “direct” hot water boiler configuration. Only these configurations can activate
the day and time program of the anti-Legionnaires’ disease function. See the following graphs. The standard fac-
tory setting for this function is “OFF”.
> > > From previous page with HOT WATER part < < <
Setting legionella program (day and time):
P r o g r a m L e g i o n e l l a
M o n 0 9 : 5 1
Press [
►
] to browse through the values that can be set at
the bottom line. The blinking value can be changed.
Press [
▲
] & [
▼
] to change the selected (blinking) value.
Press [ENTER] for confirmation screen when all settings are
done.
Confirmation screen:
A r e y o u s u r e
< C a n c e l ; > C o n f i r m
Press [
◄
] to cancel the changes made (unit will reset).
Press [
►
] to confirm the changes. The last alternation will
be blinking for a few seconds and return to base menu.
Press [MENU] to exit. The boiler will reset and go to the
operating screen.
Press [
◄
] for next SCREEN
10.11.
Setting the outdoor specifications
PARAMETERS FOR SETTING THE OUTDOOR GRAPH
When using this function the flow temperature is calculated based on the measured outdoor temperature. The
relation between the outdoor temperature and the flow temperature can be programmed with the following pa-
rameters. This setting creates the so called “heating curve”.
The boiler will recognise an outdoor sensor when it is connected. When the sensor is detected the boiler controller
will control the flow temperature based on the heating curve that is programmed.
P5 AA
Outside sensor present config (1=on 0=off)
*
When one wants to control the flow temperature based on the heating curve settings, an outdoor sensor must be
connected, and one must set this parameter at “1”. When having cascaded boilers the outdoor sensor must be
connected and this parameter must be set at “1” on the master boiler only. The heating curve that is set on the
master boiler is used for controlling the flow temperature of the whole cascade.
0 = No outdoor temperature sensor connected
1 = Outdoor temperature sensor connected
Содержание S-CB Px 120
Страница 2: ...S CB Px 120 Manual 2 ...
Страница 6: ...S CB Px 120 Manual 6 ...
Страница 33: ...S CB Px 120 Manual 33 9 4 Electrical schematics ...
Страница 34: ...S CB Px 120 Manual 34 ...
Страница 111: ...S CB Px 120 Manual 111 ...
Страница 115: ...S CB Px 120 Manual 115 weather dependent control 49 73 ...
Страница 116: ......
Страница 117: ......