Testing the Toggle Switch
Note:
There are procedures included for testing the toggle switch. However, the toggle
switch is not serviceable, and if it fails any test it must be replaced.
A. The toggle switch contact points on the PCB are aligned vertically for the single
filament Vulcan, and horizontally on the dual filament Vulcan. (see pictures below.)
B. Place a multimeter into the Continuity Check position.
C. For the single filament Vulcan, place one meter lead on each toggle switch contact of
the PCB. With the toggle switch up, there should be no continuity. When the toggle
switch is down the meter should indicate continuity.
D. For the dual filament Vulcan, put the toggle switch in the center position (off).
E. Place one meter lead on the center switch contact and the other lead on the right switch
contact. There should be no continuity. Put the toggle switch to the left. The meter
should indicate continuity. Put the toggle switch to the right. There should be no continuity.
F. Place one meter lead on the center switch contact and the other lead on the left switch
contact. There should be no continuity. Put the toggle switch to the left. There should
be no continuity. Put the toggle switch to the right. The meter should indicate continuity.
Single Filament
Toggle Switch Contacts
Dual Filament
Toggle Switch Contacts
Dual Filament
Center Switch Contact