Страница 4: ...y years of safe diving If you have additional questions after reading through the manual please do not hesitate to contact us at 386 454 1440 or via email sales salvodiving com Light Models There are...

Страница 5: ...sitions for the lid storage position and dive position Also the new lids have a completely recessed light switch labeled with the OFF position for maximum protection Completely sealed Li Po battery ca...

Страница 6: ...all of our components are housed within Delrin bodies Delrin is a lightweight low friction and wear resistant thermoplastic with good physical and processing properties and capable of operating in tem...

Страница 7: ...llwarrantyclaimswillbenullifiedif theinternalsealof the packhasbeencompromised Charging the Battery Pack Make sure to charge your battery 24 hours before diving Connect universal charger to wall outle...

Страница 8: ...ge Be certain that the lid sealing o ring is in place There is really no reason to remove this o ring during storage Periodically you should inspect the lid o ring and wipe dry any excess grease and s...

Страница 9: ...n off the light and finish preparing for your dive Post Dive To ensure years of dependable service from your light follow the steps below during your post dive breakdown Always rinse your gear after a...

Страница 10: ...commend storing your light in a cool dry environment Changing the Bulb There are no user serviceable components in the Rebel II series of LED primary lights If you are experiencing any issues please r...

Страница 11: ...breakage of the glass Note The 35W and 50W Havoc II HID primary lights have an additional collet and external lamp cover o ring at the base of the lamp cover that needs to be unscrewed and removed bef...

Страница 12: ...ase will make the O rings to slick and pressure build up during reinstallation will cause the lamp cover to push back off It is best to replace the O rings if installing a new bulb Never remove the la...

Страница 13: ...11 Inspect threads and o rings to ensure they are free from dirt and debris Connect universal charger to wall outlet Connect universal charger to tail piece...

Страница 14: ...ght head and is double o ring sealed To turn the light on rotate the head clockwise until the light head turns on It is not necessary to continue turning the light head after it comes on it will not g...