10 

 

Connect the new bulb to the lead wires from the ballast. 

 

Reinstall the bulb into the socket. Twist the bulb with a ¼ turn 
as you do so to help the wires back into the socket assembly. 

 

Holding the lamp cover with a glove or towel, reinstall the lamp 
cover with a slight twisting motion. 

 

 

The first 2-rings do the sealing. The third O-ring at the bottom 
is there to cushion the lamp cover and is not there to seal it. 

 

Do not to use grease on these O-rings. The grease will make the 
O-rings to slick and pressure build up during reinstallation will 
cause the lamp cover to push back off. It is best to replace the 
O-rings if installing a new bulb. 

 

Never remove the lamp cover unnecessarily. Most bulbs and 
lamp covers are not broken during a dive, but most commonly 
during unnecessary assembly and disassembly. 

Rebel 12 and Handheld 9 

Then Rebel 12W LED and Handheld 9W LED primary lights are unique to other 
lights because of the way they are charged and switch actuation.  These unique features 
were added to ensure the ultimate in a compact light ideal for today’s traveling diver. 

Charging 

 

Remove light head from tail piece. 

Содержание Primary Dive Lights

Страница 1: ...PrimaryLightingGuide...

Страница 2: ...U S E A N D C A R E G U I D E For Salvo Primary Dive Lights Salvo LLC 705 NW Santa Fe Boulevard High Springs FL 32643 Phone 386 454 0019 Fax 386 454 1661...

Страница 3: ...ble of Contents Lighting Innerspace One Explorer at a Time 2 Light Models 2 Warranty Information 2 Features 3 Charging and Storage 5 Pre Dive 6 Post Dive 7 Changing the Bulb 8 Rebel 12 and Handheld 9...

Страница 4: ...y years of safe diving If you have additional questions after reading through the manual please do not hesitate to contact us at 386 454 1440 or via email sales salvodiving com Light Models There are...

Страница 5: ...sitions for the lid storage position and dive position Also the new lids have a completely recessed light switch labeled with the OFF position for maximum protection Completely sealed Li Po battery ca...

Страница 6: ...all of our components are housed within Delrin bodies Delrin is a lightweight low friction and wear resistant thermoplastic with good physical and processing properties and capable of operating in tem...

Страница 7: ...llwarrantyclaimswillbenullifiedif theinternalsealof the packhasbeencompromised Charging the Battery Pack Make sure to charge your battery 24 hours before diving Connect universal charger to wall outle...

Страница 8: ...ge Be certain that the lid sealing o ring is in place There is really no reason to remove this o ring during storage Periodically you should inspect the lid o ring and wipe dry any excess grease and s...

Страница 9: ...n off the light and finish preparing for your dive Post Dive To ensure years of dependable service from your light follow the steps below during your post dive breakdown Always rinse your gear after a...

Страница 10: ...commend storing your light in a cool dry environment Changing the Bulb There are no user serviceable components in the Rebel II series of LED primary lights If you are experiencing any issues please r...

Страница 11: ...breakage of the glass Note The 35W and 50W Havoc II HID primary lights have an additional collet and external lamp cover o ring at the base of the lamp cover that needs to be unscrewed and removed bef...

Страница 12: ...ase will make the O rings to slick and pressure build up during reinstallation will cause the lamp cover to push back off It is best to replace the O rings if installing a new bulb Never remove the la...

Страница 13: ...11 Inspect threads and o rings to ensure they are free from dirt and debris Connect universal charger to wall outlet Connect universal charger to tail piece...

Страница 14: ...ght head and is double o ring sealed To turn the light on rotate the head clockwise until the light head turns on It is not necessary to continue turning the light head after it comes on it will not g...