50 WATT PIR LED Floodlight

15-07-13

Please read these instructions before commencing installation 

and retain them for future reference.

Installation Sheet  LTFL50PIR

220-240V 50W

IP44

 

Switch off the power source before installation.

 

Install a minimum distance of 1m away from ground.

 

The unit must be installed in the horizontal position (

Figure 1a

), not vertically (

Figure 1b

).

SAFETY PRECAUTIONS

 

                        

            

             

              

 1a                    

HORIZONTAL    

               

            1b 

  VERTICAL

  

 

1. If in doubt consult a professional electrician.
2. Unscrew the floodlight from its wall bracket as indicated in 

Figure 2, part 4

.

3. Line up the wall bracket holes and drill three holes into the wall. Use appropriate size rawl 
    plugs and screws to fix the bracket to the wall.
4. Screw  the floodlight on to its wall bracket and tighten firmly, angling the light as required.
5. When connecting the power cable into the PIR sensor housing, please follow the wiring
    instructions opposite. 
6. After connecting the power supply, the installation has been completed.

Figure 1a & 1b

INSTALLATION INSTRUCTIONS

Figure 2

CHOOSING A MOUNTING LOCATION

 

For the best results, fix your sensor on a solid surface, 1.8~2.5M above the ground.

 

For outdoor installation, a location under eaves is preferable.

 

Avoid aiming the motion sensor at pools, heating vents, air conditioners or objects that may 

  change temperature rapidly.

 

Do not allow sunlight to fall directly on the front of unit.

 

Try to avoid pointing the unit at trees or shrubs or where the motion of pets may be detected.

 

When choosing the mounting position consider that the sensor is more sensitive to motion across 

  the detection field (A) and less sensitive to motion directly towards the sensor (B)

 (

Figure 3

).

 

Select a location for the unit based on the coverage angles shown in 

Figure 4

.

1

2

3

4

SENSOR

LESS SENSITIVE

SENSOR

MORE SENSITIVE

SENSITIVITY TO MOTION

Figure 3

COVERAGE ANGLES

Figure 4

UNIT (M)

 

WIRING INFORMATION

 

Wired with three

core (w/o plug)

240V Input (Figure 5)

Brown = Live 

Blue= Neutral

Green/Yellow = Earth 

240V Input   Figure 5

Walking Towards
Walking across

1
2

COVERAGE RANGE

Live

Neutral

Earth

PIR

L

N

E

L

N

L'

N

LED Floodlight

Brown = Live wire - L

Blue =  Neutral Wire - N

Green/Yellow = Earth wire - E

 

Pulse Override facility

 to enable lighting to be switched on for long periods using an existing switch.

  For pulse override switch the power OFF then ON again within 2 seconds to enable constant light. 
  In constant light mode turn OFF and ON after 5 seconds to enable sensor mode.