background image

R1

IP66

OUTDOOR

MODEL

P06005000

www.lanzini.it

EN

INSTRUCTIONS

INSTALLATION, USE AND MAINTENANCE

Warning!

 Security of the fitting is guaranteed only with the appropriate use of the 

following instructions: therefore it is necessary to preserve them.

Warning!

  Before  connecting  to  the  main  network,  during  assembly  or 

replacement of the product, make sure to disconnect the tension.

Warning!

 The product has to be repaired only by professional technicians or by the 

manufacturer.

- During product installation respect carefully the plant rules.

- The fitting should be used only if complete with its protection screen; This is a 

polycarbonate lens(3mm thick tempered glass can be supplied on request).

- For any replacement contact the manufacturing company. 

- The fitting must be installed by a professional electrician.

- The fitting cannot  be modified or tampered with in any way, any modification may 

compromise  security  by  making  it  dangerous.  The  manufacturer  declines  any 

responsibility for the modified products. 

- Class I fitting must be connected to the ground circuit of the electrical plant.

- Keep at least 1 m between the fitting and the illuminated surface. 

- Fitting suitable for outdoor applications. Protection degree IP66.

- Fitting suitable for direct mounting on normally inflammable surfaces.

- Remove the wall mounting flange by unscrewing the n° 2 side screws.

- Install the wall fixing flange using n°2/3 fischer, with a minimum diameter of 6 

mm. 

- Make sure that the fixing flange is securely connected to the wall (fig. A). 

-  Connect  the  power  cables  to  a  triple  connector  that  can  guarantee  a  minimum 

protection degree IP67 (fig.B). Lanzini provides this connector (code L93062000) as 

a separate mounting kit, on request; alternatively, you can use a similar connector.  

- Position the fitting with the required inclination using the appropriate goniometer 

placed on the bracket, and tighten the screws previously removed (fig. C).

- Make sure you have done everything correctly and reconnect  the tension (fig. D). 

- Do not stare at light source.

Warning!

 Risk of electric shock

- For use in environments where an accumulation of non-conductive dust on the 

luminaire

1 m

Power supply: 

220-240 V AC - 50/60 HZ

 

Power 

Weight 

Dimensions 

Surface exposed to the wind

80W 

2,7 Kg  

348×190×94 mm 

0,051 m²  0,011 m²

100 W 

2,7 Kg  

348×190×94 mm 

0,051 m²  0,011 m²

110 W 

2,7 Kg  

348×190×94 mm 

0,051 m²  0,011 m²

Operating temperature: 

-40° +45°C 

Insulation class: 

I

BLANK EXTERNAL DRIVE

EP s.p.a. Via del Commercio 1 - 25039 - Travagliato (BS) - ITALY

IT

-Questo prodotto contiene una sorgente luminosa di efficienza energetica classe 

EN

-This product contains a light source of energy efficiency class

D