The insulation testing results must be at least
the test values given in the following two ta-
bles.
–
For insulation testing, contact the author-
ised service centre.
The exact procedure for this insulation testing
is described in the workshop manual for this
industrial truck.
NOTE
The electrical system of the industrial truck
and the drive batteries must be checked sepa-
rately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal volt-
age U
Batt
Test values
Battery
50 VDC
Batt+
Batt-
Battery tray
24 V
> 1200 Ω
100 VDC
48 V
> 2400 Ω
100 VDC
80 V
> 4000 Ω
Test values for the industrial truck
Nominal volt-
age
Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 V
50 VDC
Min. 50 kΩ
> 24 kΩ
48 V
100 VDC
Min. 100 kΩ
> 48 kΩ
80 V
100 VDC
Min. 200 kΩ
> 80 kΩ