NOTE
Battery maintenance is carried out in accord-
ance with the battery manufacturer's operating
instructions. The operating instructions for the
battery charger must also be followed. Only
the instructions that came with the battery
charger are valid. If any of these instructions
are missing, request the relevant instructions
from the dealer.
The battery maintenance information is com-
posed of the following sections: "Checking the
status, acid level and acid density of the bat-
tery", "Checking the battery charge status",
"Charging the lead-acid battery" and "Equalis-
ing charge to maintain the battery capacity".
Checking the battery condition,
acid level and acid density
WARNING
The electrolyte (diluted sulphuric acid) is
poisonous and corrosive!
–
Observe safety regulations for han-
dling battery acid; see the chapter en-
titled "Battery acid".
–
Wear personal protective equipment
(rubber gloves, apron and protection
goggles).
–
Rinse away spilt battery acid immedi-
ately using plenty of water!
CAUTION
Risk of damage!
–
Note the information in the operating instructions
for the battery.
–
Remove the battery from the industrial
truck.
–
Inspect the battery for any cracks in the
housing, raised plates and acid leaks.
–
Have defective batteries repaired by the au-
thorised service centre.
Operation
4
Handling the lead-acid batteries
213
50078078001 EN - 07/2022 - 04
Содержание LXT 120
Страница 2: ......
Страница 12: ......
Страница 13: ...1 Foreword ...
Страница 37: ...2 Safety ...
Страница 59: ...3 Overviews ...
Страница 62: ...Overviews 3 Display control unit 50 50078078001 EN 07 2022 04 ...
Страница 63: ...4 Operation ...
Страница 117: ...The softkey is also located in the Driving menu Operation 4 Lighting 105 50078078001 EN 07 2022 04 ...
Страница 265: ...5 Maintenance ...
Страница 285: ...6 Technical data ...
Страница 323: ......
Страница 324: ...STILL GmbH 50078078001 EN 07 2022 04 ...