54
MS 231, MS 231 C, MS 251, MS 251 C
Installing
:
Push the sleeve (1) into the
loop (arrow) of contact spring (2)
as far as stop.
:
Position the contact spring (1)
against the guide (arrows).
:
Lift the contact spring (1) a little
and ease it over the tab (arrow).
– take care not to overstretch the
contact spring.
Before pushing the contact
spring (1) fully home, lift it a little
and ease it over the switch level –
no more than 2 mm.
2310RA424 TG
1
2
2310RA152 TG
2
1
2310RA153 TG
1
:
Push the contact spring (1) into
the guide (arrows) until it is
engaged by the tab.
– Install the filter base,
b
12.3
:
Check operation
– short circuit wire's terminal
sleeve must touch the contact
spring (arrow) in position "
0
".
– Reassemble all other parts in the
reverse sequence.
2310RA154 TG
1
2310RA155 TG
All manuals and user guides at all-guides.com