S Series FW 3.02.02
www.stenner.com
96
TUBE REPLACEMENT
continued
S30 – CENTER THE TUBE
1.
Lift the latch located between the tube fittings, leaving the end of
the latch engaged with the lip on the tube housing cover. Leave the
latch on the opposite side engaged.
Illustration N
2.
Plug the pump in. Depress the prime button and turn the tube
fitting on the suction side not more than 1/8 of a turn in the
direction the tube must move
Illustration O
3.
Do not let go of the fitting until the tube rides approximately in the
center of the rollers.
4.
Release the prime button, let go of the fitting, and secure the latch
between the fittings.
Illustration P
5.
Inspect the suction and discharge lines, point of injection, and check
valve for blockages. Clean and/or replace as required.
6.
Reconnect the suction and discharge lines.
7.
Prime pump and verify operation.
8.
Place pump in desired operating mode.
N
Prepare to center tube
Closed latch
Front of
latch secure
Back of
latch open
O
Center tube
P
Secure latches
1/8 Turn