PPM FEED – VARIABLE FLOW, HALL EFFECT
page 6 of 6
• The pump pr12VDC to the meter.
• The meter's K factor (pulses per unit of volume) is specified by the meter manufacturer.
• Typically, the meter manufacturer specifies a minimum flow rate for the meter. The pump minimum process flow rate
setting should not be set below the meter manufacturer's recommendation.
Concentration
100.00 %
yes/no
set
Meter K Factor P/G
1000.0000
adjust
set
Feed Rate
_ 10.0 PPM
adjust
set
Specific Gravity
1.14
adjust
set
Go to top of
PPM Variable Flow
menu
Set the Meter K Factor.
Gallons or Liters is selected in
Units
under
Configuration.
Set the dose rate in parts per
million (ppm).
Set the Chemical Concentration.
Set the Chemical Specific Gravity.
CONTROL MODES MENU
continued
PPM Feed Variable Flow
- Program Settings
- Alarm Settings
- Go to PPM Feed Menu
Continued from previous page
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.