INSTALL THE TUBE/
EXPAND THE ROLLER ASSEMBLY
1.
Ensure the power to the pump is off and the input signal is
disconnected.
2.
Install the tube.
S30
- Place the new tube in the pump head and use your fingers to
center it on the rollers.
Illustration H
S40
- Place the new tube in the pump head.
IMPORTANT: DO NOT TWIST THE
TUBE
during installation. To ensure it
doesn't twist, keep the tube positioned
so the printed description stays
aligned along the length of the tube.
- Use your fingers to center the tube on
the rollers.
3.
Place the tube housing cover (feet first) on the tube housing, affix the
front of the latches to the cover lip and then press the latches back
to secure. Be sure the cover is seated with the sleeve bearing on the
shaft and is flush with the housing before latching.
Illustration I
4.
With the cover latched, plug the pump in. Depress the prime
button to allow the pump to run the roller assembly in its
collapsed position for four minutes.
Illustration J
5.
Unplug the power cord to ensure the power to the pump is off.
6.
Remove the tube housing cover and flip to use as a tool in the
next step.
7.
Align the center of the inverted cover with the center of the roller
assembly so that the three holes on the face of the cover align with
the three knurled lugs on the roller assembly. Position the cover
feet near the bottom.
Illustration K
NOTE: The roller assembly needs to be expanded so the tube is
pressed against the tube housing wall.
8.
Hold the pump securely. Use the cover as a wrench and quickly
(snap) rotate the roller assembly clockwise to expand the roller
assembly. The tube will be pressed against the tube housing wall.
Illustration L
9.
Apply a small amount of AquaShield
™
to the cover bushing ONLY.
DO NOT lubricate the pump tube.
Illustration M
10.
Place the tube housing cover (feet first) on the tube housing, affix the
front of the latches to the cover lip and then press the latches back to
secure. Be sure the cover is seated with the sleeve bearing on the
shaft and is flush with the housing before latching.
Illustration I
US and Canada 800.683.2378, International 904.641.1666
S Series FW 3.02.02
95
TUBE REPLACEMENT
continued
The square ends
help prevent the
tube from twisting
during operation.
I
Install cover feet first
K
Align cover feet near bottom
H
Place new tube
J
Depress the prime button
3 Lugs
Center of Roller Assembly
Cover Feet
Cover Feet
Prime Button
Cover Bushing
L
Expand roller assembly
M
Apply Aquashield
™
to cover bushing