S Series FW 3.02.02
www.stenner.com
52
Continued on next page
PPM Feed Variable Flow
- Program Settings
- Alarm Settings
- GO TO PPM FEED MENU
CONTROL MODES MENU
continued
PPM Feed
- Constant, Flow Switch
- Variable, Hall Effect
- Go to Main Menu
PPM Feed Variable Flow
- Program Settings
- Alarm Settings
- GO TO PPM FEED MENU
PPM Feed
- Constant, Flow Switch
- Variable, Hall Effect
- Go to Main Menu
To
Main Menu
PPM FEED – VARIABLE FLOW, HALL EFFECT
page 5 of 6
A process flow that exceeds the maximum programmed flow rate will lead to incorrect dosing. It is
recommended to the high flow alarm. Alarms activate when settings are exceeded.
PPM Feed Variable Flow
- Program Settings
- Alarm Settings
- GO TO PPM FEED MENU
To
PPM Feed Menu
Stop Pump on H Alarm?
No
adjust
set
Alarm if speed>100%?
Yes
adjust
set
Delay to Activate
_ _ 0 second(s)
adjust
set
Yes
No
Go to
PPM Variable
Flow
menu
Go to
PPM Variable Flow
menu
After completing
Program and Alarm
Settings
, select
“Go To Main Menu”
and press ENTER
to return to the
Main Menu.
Select “Yes” to enable high flow (process flow > 100%)
alarm. Select “No” to not enable the high flow alarm and
return to the
PPM Variable Flow Control
menu.
Set the delay until the
alarm is to be activated
after process flow
exceeds 100% (0 to
999 seconds).
Select “Yes” to stop the
pump in the event of a
high flow alarm. Select
“No” to allow the pump to
continue running in the
event of a high
flow alarm.
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.