S Series FW 3.02.02
www.stenner.com
94
REMOVE THE PUMP TUBE
continued
6.
Collapse the roller assembly.
S30
Hold the pump securely, use the tube housing cover as a wrench
and quickly (snap) rotate the cover counterclockwise to collapse
the roller assembly. The tube will no longer be pressed against the
tube housing wall.
Illustration E
S40
Hold the motor securely with one hand. With the other hand, hold
the tube housing cover with your forefingers inside the top lip of the
cover. Use the cover as a wrench and with your palm quickly (snap)
rotate the cover counterclockwise to collapse the roller assembly.
The tube will no longer be pressed against the tube housing wall.
7.
Remove and discard the pump tube.
Illustration F
8.
Remove the roller assembly and housing. Set them aside to
re-install later.
9.
Use a non-citrus all-purpose cleaner to clean chemical residue
from the tube housing, roller assembly and cover.
10.
Check the housing for cracks. Replace if cracked.
11.
Ensure the rollers turn freely. Replace the roller assembly if the
rollers are seized or worn or if there is a reduction or lack of output
from the pump.
Illustration G
12.
Reinstall clean tube housing.
13.
Apply AquaShield
™
to the shaft tip.
14.
Install the roller assembly.
E
Collapse roller assembly
F
Remove tube
G
Check rollers
TUBE REPLACEMENT
continued