Display
Parameters
min.
max.
Factory
setting
Functionality
T
T
P
ara
SET
Storage tank loading
strategy
dIFF
1)
,
AbS
2)
The loading strategy depends
on the storage tank system
used and the usage of the
system.
dIFF
: Highest efficiency. The
control target is the tem-
perature difference between
the collector and the storage
tank.
3)
AbS
: Useful when the system
requires particular tempera-
tures, e.g. to avoid switching
on the external back-up heat-
ing system.
The control target is the tem-
perature of the collector.
3)
Control target of dif-
ferential temperature
loading (
dIFF
)
4 F
100 F
16 F
Control target of
absolute temperature
loading (
AbS
)
32 °F
200 °F
140 °F
P
ara
SET
R1
pump type
AC
,
HE
AC
Notice
Danger of malfunctions in the
controller or damage to the
components.
With a high-efficiency pump,
HE
must
be set and with a
standard pump
AC
must
be
set!
Set speed control to
oFF
when an external relay is con-
nected or speed control is not
wanted.
Pump characteris-
tics (only
HE
)
bA
,
bb
,
C
(see p. 14)
–
Speed control
on
,
oFF
oFF
Minimum speed
(only
AC
)
30 %
100 %
50 %
Minimum speed
(only
HE
+
bA
)
0 %
100 %
25 %
Minimum speed
(only
HE
+
bb
)
0 %
100 %
75 %
Tab. 3: Parameters
1)
dIFF
is defined as a fixed value for swimming pools.
2)
The factory setting depends on the system that has been set.
3)
The pump speed is adjusted accordingly to achieve the control target.