12
742.110 | 14.50
EN
Commission the controller for the first time as follows:
Setting the time
1. Apply power to the controller.
– The time
12:00
is displayed.
–
12
flashes (Fig. left).
– Backlighting is red.
2. Press
to set the hours.
3. Press
SET
. The minute flashes.
4. Press
to set the minutes.
5. Press
SET
. The set time is displayed.
Selecting a system
6. Press
.
System 1.1
is displayed,
1.1
flashes (Fig. left).
7. Press
to select a different system.
8. Press
SET
.
If
System 0.1
was selected in step 7, then continue with
step 18.
Setting pump 1 (output R1)
9. Press
.
AC
and flash (example in Fig. left).
10.
Notice
Standard pump: Select
AC
!
High-efficiency pump: Select
HE
!
Press
to set the type of pump 1.
11. Press
SET
.
12.
Notice
Pay attention to the pump characteristics when selecting
HE
(high-efficiency pump).
Only if
HE
was selected in step 10:
Press
to set the characteristics of the high-efficiency
pump; see Tab. 2 and Fig. 6 on p. 14.
13. Press
SET
:
– If
bA
or
bb
was selected in step 12,
SC
is displayed;
off
,
and flash (example in Fig. left;
SC
= Speed control).
– If
C
was selected in step 12, then continue with step 18.
14. Press
to switch on the speed control if necessary (
on
flashes).
15. Press
SET
.
If
off
was selected in step 14. then proceed with step 18.
Содержание TR-A501T-U
Страница 47: ...47 742 110 14 50 EN 18 Notes ...
Страница 48: ...48 742 110 14 50 EN 742110 ...