33
742.110 | 14.50
EN
V
F
unc
SET
Type 2: Flow rate of the pulse
water meter in litres/pulse; see
the pulse water meter data
sheet.
1.0
gal...10.0
gal
,
1
l
,
10
l
,
25
l
–L
(no flow
rate value
selected)
Glycol proportion
0 %
60 %
40 %
Supply sensor input (warm)
1 ... 5
–
Return sensor input (cold)
1 ... 5
–
T
T
F
unc
SET
on
CO
2
display
on
,
oFF
oFF
T
T
F
unc
SET
lbs
CO2
/kWh
therm
0.100
2.500
1.918
2)
1)
tyP
1
: Calculation of the flow rate from the pump speed. To do this, the displayed flow rate values are entered
at two measuring points (pump speed min. and max.).
tyP
2
: Determining the flow rate using a pulse water meter. The flow rate of the pulse water meter in
litres/impulse is entered.
2)
Source: Hawaiian Electric Co., Inc. HECO Residential Rebate Program, Solar water heating system information
sheet (2007): 1.918 Ibs
CO2
/kWh
therm
.
10.3.9 Circulation
Switches a circulation pump on and off on a temperature and/or time
controlled basis. The pump must be connected to output
R1
.
Temperature control
: If the temperature in the circulation return falls
below the T
on
value, then the circulation pump is switched on until the
T
off
temperature is reached.
Time control
: The circulation pump is switched on when the current
time lies within one of 3 configurable time windows.
Temperature and time control
: The circulation pump is switched on
when the switch-on conditions for the temperature
and
time control are
satisfied.
Note
Install the circulation sensor at least 1.5 m (60 inch) away from the
storage tank to avoid false measurements due to heat conduction of the
pipes.