Midilift XLplus
Maintenance Guide
Jan
2014
Issue
4
36
17.9 Safety chain switch locations
G1
Shutdown keyswitch
Main entrance landing station
G1A Overspeed
governor
switch
Mounted on the overspeed governor
G1B Overspeed governor rope switch
Mounted on the tension pulley assembly (pit)
G1C Pit stop switch
Mounted on the base plate assembly (pit)
G1D Test controls stop switch
Located in the upper landing control box
G1E Landing controller stop switch
Located in the upper landing control box
G2
Hand-winding manual release switch Located in the upper landing control box
G2A Safety gear moniter switch
Mounted on the inside of each sling upright
G3
Ultimate limit switch
Mounted on the outside of one sling upright
G4
Carriage stop switch
Mounted on the COP within the cabin
G5
Landing door beak contacts
Between the door and frame at each landing
G6
Solenoid lock switches
Mounted on each solenoid lock (at each landing)
G7
Solenoid feed monitor
G7 terminal can be found on carriage control PCB
G7A Invertor alarm / fault
Located in the upper landing control box
G7B Cabin floor safety edge
Mounted on the entrance side of the floor assembly
G7C Cabin roof safety edge
Mounted on the entrance side of the roof assembly
G8
Ceiling safety switch
Mounted on theslam side of the ceiling assembly
Содержание MIDILIFT XL PLUS