Midilift XLplus
Maintenance Guide
Jan
2014
Issue
4
24
The autodialer must dial out correctly, and both the microphone and the speaker must be clear to the user and the
operator. Before testing the autodialer, acquire the programmed number and inform the operator about the
following test.
If autodialer is installed with induction loop, perform all the necessary tests to ensure system is working correctly.
•
Required
action
Carry out any immediate remedial work required, wiring or re-programming the unit. Access can be gained through
the COP (
4.2 Cabin operating panel (COP) removed, pg 4).
If further work is required, inform supervisor and
customer and record any manufacturer details and part numbers necessary.
15.2 Telephone
•
Required
standard
The telephone must be free from damage and clear at both ends of the line.
•
Required
action
Carry out any immediate remedial work required, wiring or re-programming the unit. Access can be gained through
the COP (
4.2 Cabin operating panel (COP) removed, pg 4).
If further work is required, inform supervisor and
customer and record any manufacturer details and part numbers necessary
15.3 Intercom
•
Required
standard
The intercom must connect correctly, and both the microphone and the speaker must be clear to the user and the
operator. Before testing the intercom, inform operator of the subsequent test.
•
Required
action
Carry out any immediate remedial work required. Access can be gained through the COP (
4.2 Cabin operating
panel (COP) removed, pg 4).
If further work is required, inform supervisor and customer and record any
manufacturer details and part numbers necessary
15.4 Power
door
operator
•
Required
standard
The door operation is to be as smooth and as quiet as possible. There must be no vibration, juddering or rumbling
at any stage of the door cycle. Doors are to come to halt at open and closed points quietly and not slam into
uprights. Speed changes in door travel are to be smooth and happen at the correct part of the door travel.
•
Required
action
Adjust doors and door closers as necessary to achieve correct operation. This will include altering the speed
settings to ensure door closes smoothly and with the correct speed.
If there is excessive damage to the door or door closer which are not immediately resolvable make note of required
part numbers and inform customer and supervisor on possible lift shut down.
Details on the operator setup can be found in the electrical manual, this should be stored in the upper landing
control panel (
4.3 Upper floor landing controls, pg 4).
15.5 Fire alarm shut down
•
Required
standard
Содержание MIDILIFT XL PLUS
Страница 1: ...MIDILIFT XL PLUS MAINTENANCE GUIDE...