Midilift XLplus
Maintenance Guide
Jan
2014
Issue
4
25
If selected this option will ensure the lift is brought down to ground floor on the input of the building fire alarm. Once
at ground the lift should announce that the user can exit the lift using the ground floor button. At this point the only
function still effective will be the operation of the ground floor button situated in the cabin.
•
Required
action
If for any reason this function does not work as described, carry out any immediate remedial or inform the
supervisor and customer on any future work required.
15.6 UPS
•
Required
standard
With power cut to lift, the cabin must be able to run down to ground floor powered by the UPS. Different levels of
emergency power may be supplied at the UPS, from only completing one journey to ground floor or completing
numerous journeys. Check lifts documentation for this information
•
Required
action
If for any reason this function does not work as described, carry out any immediate remedial or inform the
supervisor and customer on any future work required.