GENERAL INFORMATION
9
Designation
in Fig.2
Designation
on main unit
Use
ESC
Action canceling button (return on "one step")
FUNC
Button for turn on of various modes
ENTER
Button for confirm action
MODE
Button to call the mode selection menu
7
Accumulator charge indicator
8
Slot for connection of the charger
9
Mini-USB connector for connection to the PC
10
Information plate with the serial number
11
Support
12
Integrated speaker phone
ELECTRONIC SWITCH
The Analyzer has an integrated Electronic Switch (hereinafter "Switch") designed to increase
the efficiency of testing multi-wire cables.
Automated and manual control modes of the Switch allow to connect all combinations of wire
pairs of a multi-wire cable to the RJ45 socket "INPUT" (Fig.2, item 4).
The control of the Switch is impossible when testing power mains.
1.3.2. ADAPTER FOR TESTING OF THE POWER MAINS
The adapter
(Fig.1, item 7)
is used for connect the main unit to the tested power mains. LED
indicator in the plug, indicates the presence of voltage in the tested cable.
The adapter has the RJ45 plug. The contacts #1 and #2 are connected. Other contacts are not
involved.
1.3.3. PATCH CORD FOR CONNECTING TO THE PC SOCKET (RJ45)
Standard patch cord
(Fig.1, item 20)
, is used for connect the main unit to RJ45 PC socket.
1.3.4. PATCH CORD FOR CONNECTING TO THE TELEPHONE SOCKET (RJ11)
The patch cord
(Fig.1, item 21)
is used when testing the telephone cable that are equipped
with RJ11 sockets.
The patch cord is equipped with RJ45 and RJ11 connectors. On the RJ45 connector six contacts
are involved (#2 - #7). Two extreme contacts (#1 and #8) are not connected.
1.3.5. PATCH CORD RJ45/TV(M) FOR CONNECTING TO THE TV SOCKET TV(F)
The patch cord
(Fig.1, item 19)
is used when testing television receivers, cable and terrestrial
television cables.
The cable is equipped with RJ45 and TV(f) connectors. On the RJ45 connector, only two
extreme contacts (#1 and #2) are involved. Other contacts are not connected.