Using the Rotation mode
Repeatedly pressing the
button 4
toggles through
0, 80, 200, 600,
750
rpm
regardless if the unit is in
automatic or manual mode.
At 0 rpm, the beam stops automatically close to the +Y- axis center position
.
In
automatic mode,
using
buttons 5/8 increases/decreases rotor speed
from 0 to 80 and then up to
750
rpm
continuously in 10 rpm increments.
Pointing mode
At 0 rpm, buttons 6/7 move the beam to the left/right side. When set up vertically at 0 rpm, button 5/8 move the
beam clockwise/counterclockwise.
Note:
Press and hold button 4 for three seconds to change the unit from rotation mode (default) into scan mode.
Using the Scan mode
Press and hold
button 4
at the Standard Display
for three seconds
to change the unit into
scan mode.
Quickly press and release
button 4
to toggle between the
pre-selected scan sizes 5, 15, 45, 90, 180 degrees
and 0;
regardless if the unit is in automatic or manual mode.
When working in
horizontal automatic mode,
press and hold
button 5/8 to increase/decrease the line size
in 5 degrees increments.
Press and hold
button 6/7
moves the
scan line
to the
right/left direction.
When used in
automatic vertical mode,
pressing and holding
button 5/8
moves the
scan line
counterclockwise/clockwise.
When set up
vertical,
pressing and holding
button 6/7
moves the
scan line
into the
right/left direction
regardless if
in automatic or manual mode.
Note:
Press and hold button 4 for three seconds to change the unit back to rotation
mode (default) mode.