Manual Spot Search mode
The Spot Search mode is used for layout applications by detecting the plumb beam manually using the
Spot Finder SF601
and can be activated in
horizontal and vertical automatic and manual mode
.
Press and release the
MENU button 1
at the Standard Display and select
Spot Search
.
Pressing
button 4
activates the fan beam while the rotation speed changes to 750 rpm
and the unit goes back to the standard display.
The 4 red LEDs around the center hole guide the user to the plumb
beam‘s center position - all 4 LEDs on
=> confirmation the SF601 has been set to the correct center position.
Note: Manual Spot Search
can also be activated any time by
turning on the Spot Finder SF601
.
Turning Off the SF601 deactivates the Spot Search mode immediately by deactivating the fan beam.
Special Features
– Using SF601