Chapter 8 – Replacing the LCM
68
Continuing Backups
If the LCM is malfunctioning, you have no control of the library through the Library
Controller (LC) on the front panel or through the Remote Library Controller (RLC). A
malfunctioning LCM can also affect robotics, drives, and QIPs. Backups are interrupted
if the robotics, drives, or QIPs are affected and cannot be restarted until after the LCM
is replaced.
Preparing for Replacement
Whenever you modify the configuration of the library or a partition, you have the
option of saving the configuration to a USB storage device, as described in “Saving the
Library Configuration” in the
Spectra T200 &T380 Library User Guide
. The saved
configuration can be used to restore a lost configuration.
If you previously saved the library configuration on a USB storage device or uploaded
it to a file on your computer, locate the most current configuration file before
beginning the replacement procedure. You can use this saved configuration to restore
the library configuration after you replace the LCM.
Caution:
Do not attempt to save the library configuration if the LCM is
malfunctioning. Any information saved at this point may be
corrupted.
Replacing the LCM
1.
Power off the library as described in
Power Off the Library
on page 21.
2.
Disconnect any cables connected to the LCM and remove the USB storage device, if
present.
3.
Use a #2 Phillips screwdriver to remove the two screws securing the LCM to the
chassis (Figure 8-2).
Figure 8-2
Remove the screws securing the LCM to the chassis.
Screw
Screw
Содержание T-Series Spectra T200
Страница 1: ...Spectra T200 T380 Libraries Assisted Self Maintenance Guide PN 91010002 Revision A ...
Страница 10: ...Contents 10 Notes ...
Страница 26: ...Chapter 2 Using a USB Storage Device 26 Notes ...
Страница 30: ...Chapter 3 Replacing the Air Filter 30 Notes ...
Страница 62: ...Chapter 6 Replacing a QIP or Bus Expansion Module 62 Notes ...
Страница 100: ...Chapter 9 Replacing the Transporter 100 Notes ...
Страница 110: ...Index W 110 Notes ...