Operating Instructions
34
1096.0799 | VU / VH Series
10/2010
Defect
Cause
Rectification
Motor protection triggered
Short-circuit in the motor winding
►
Check the motor winding
Motor protection switch has not been correctly
set/is defective
►
Check setting/replace the motor protection
switch
Motor overload
►
Check/reduce the operating liquid flow rate
Excessive backpressure in the outlet nozzle
►
Reduce
backpressure
Excessive share of liquid in the suction flow
►
Reduce the share of liquid
Blocked suction-side fitting
►
Open the suction-side fitting
Motor or vacuum pump blocked
►
Motor does not start
Excessive power con-
sumption of the motor
Motor overload
►
Check/reduce the operating liquid flow rate
Excessive backpressure in the outlet nozzle
►
Reduce
backpressure
Excessive share of liquid in the suction flow
►
Reduce the share of liquid
Blocked suction-side fitting
►
Open the suction-side fitting
Density/viscosity of the operating liquid is too high
►
Use an operating liquid complying with the
density recommended in the data sheet.
Contact the manufacturer
Impeller rubs against the inter casing
►
Disassemble the pump, properly set the inter
casing/impeller gap size
Pump contamination/calcification
►
Flush/descale/disassemble the pump, clean
it
Pump does not produce
vacuum
Lacking operating liquid
►
Check the operating liquid supply
Leak in the suction pipe
►
Check/seal the suction pipe and connections
Wrong direction of rotation of the motor
►
Check direction of rotation/swap the 2
phases if need be
Insufficient vacuum
Leaking system
►
Check the system, seal leaking spots
Excessive operating liquid flow rate
►
Reduce operating liquid flow rate
Insufficient operating liquid flow rate
►
Increase operating liquid flow rate
Operating liquid too hot
►
Cool down the operating liquid
Leak in the suction pipe
►
Check/seal the suction pipe and connections
Wrong direction of rotation of the motor
►
Check direction of rotation/swap the 2
phases if need be
Motor speed too low
►
Increase speed, contact the manufacturer
Gas or liquid channels subject to calcification
►
Descale/disassemble the pump, clean it
Internal components are subject to wear
►
Replace the affected components
Worn-out control valve
►
Replace the control valve
Worn-out shaft sealing
►
Replace the shaft sealing
Amount of drained liquid too small
►
Provide for free drainage of the liquid and
ensure that the connections are not ob-
structed
Pump has not been correctly dimensioned
►
Replace the pump
Strange noise
Pump cavitation
►
Install an anti-cavitation valve or
►
Equip the suction pipe with a ventilation
valve
Excessive share of steam in the suction flow
►
Reduce the share of steam or provide for
condensation upstream the vacuum pump
Suction-side fitting closed
(excessive inlet pressure)
►
Open the suction-side fitting or provide for
cavitation protection
Excessive operating liquid flow rate
►
Reduce operating liquid flow rate
Excessive speed
►
Reduce speed, contact the manufacturer