![Speck pumpen VH 110 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/speck-pumpen/vh-110/vh-110_operating-instructions-manual_1341817031.webp)
Operating Instructions
10/2010
1096.0799 | VU / VH Series
31
9.
Installation of bearing housing on discharge casing (non-
drive side)
Force the bearing cover (360.1) into the bearing hous-
ing (330), adjust it and fasten it with hexagon head
screws (901.1).
Force the bearing housing into the discharge casing
(107) and fasten it with hexagon head screws (901.3).
Push the ring (500) onto the shaft.
Press-fit the rolling bearing (320) into the bearing
housing (330).
Push the lock washer (931) onto the shaft.
Screw the shaft nut (921) into position, tighten it and
secure it with the lock washer (931).
Force the bearing cover (360) into the bearing housing,
adjust it and slightly fasten it with hexagon head
screws (901.1).
10. Pump
adjustment
Position the pump horizontally and adjust it on level
ground.
Tighten the hexagon nuts (920) of the casing bolts
(563) crosswise.
11. Setting impeller position (non-drive side)
Loosen the hexagon head screws (901.1) on the bear-
ing cover (360.1).
Fasten the hexagon head screws (901.1) on the bear-
ing cover (360) until the impeller is in contact with the
inter casing of the suction casing.
Start the gauge at the front (drive side) of the shaft.
Loosen the hexagon head screws (901.1) on the bear-
ing cover (360).
Tighten the hexagon head screws (901.1) on the bear-
ing cover (360.1) until the impeller is in contact with the
inter casing of the discharge casing.
Halve the determined measure X and adjust the shaft
by half the measure X (towards drive side).
Fasten the shaft in this position by evenly tightening
the hexagon head screws (901.1) on the bearing cov-
ers (360/360.1).
Verify unobstructed movement of the pump. Manually
rotate the pump shaft.
12. Pipe
installation
Put the seals (400) and pipes (700) onto the suc-
tion/discharge flange, fasten them with hexagon head
screws (901) and hexagon nuts (920).
7.5.14 Assembly of VU/VH 500/600/
800/1200/1600
Cross-sectional drawing VU 500/600/800/1200/1600
Cross-sectional drawing, page 59
Cross-sectional drawing VH 500/600/800/1200/1600
Cross-sectional drawing, page 61
1.
Installation of valve flaps
Not applicable to VH 500/600/800/1200/1600 and VU 500
VU 600/1200/1600 inter casings (137/137.3)
VU 800 inter casing (137.3)
Put the stop plate (598/598.1) and the flap valve (746)
onto the inter casings (137/137.1).
Screw the hexagon head screws (901.5) with screw
locking (Loctite®) into the inter casings.
2.
Installation of inter casings on suction/discharge casing
Adjust the inter casing (137) (marks) and force it into
the suction casing (106).
Adjust the inter casing (137.3) (marks) and force it into
the discharge casing (107).
Screw hexagon socket head screws (914) through the
suction/discharge casing into the inter casings and fas-
ten them.
Additional steps for VH 800/1200/1600
Adjust the inter casings (137.1/137.2) (mark),
force them into position and compress them.
Additional steps for VH 500/600
Insert the packing gland (461) into the inter casing
(137.2).
Adjust the inter casings (137.1/137.2) (mark),
force them into position and compress them.
3.
Installation of impeller and pump shaft
Insert fitting keys (940/940.1) into the pump shaft (211)
(non-drive side).
Insert an O-ring (412) into the groove of the shaft pro-
tection sleeve (524).
Push the shaft protection sleeve (524) and the lock
washer (931) onto the pump shaft.
Screw the impeller nut (922) onto the pump shaft.
Vertically clamp the pump shaft with the drive side
pointing up.
VU 500/600/800/1200/1600
Push the impeller (230) onto the pump shaft.
The impeller blades must be tilted in the direction of rota-
tion.
VH 500/600/800/1200/1600
Push the impeller (230.1) onto the pump shaft.
The impeller blades must be tilted in the direction of rota-
tion.
Insert O-rings (412) into the grooves of the shaft
protection sleeve (524.1).
Push the shaft protection sleeve (524.1) onto the
pump shaft.
Push the inter casings (137.1/137.2) jointly over
the shaft protection sleeve (523) .
Insert the fitting key (940) into the pump shaft.
Push the impeller (230) onto the pump shaft.
The impeller blades must be tilted in the direction of rota-
tion.
Insert the fitting key (940.1) into the pump shaft.
Insert an O-ring (412) into the groove of the shaft pro-
tection sleeve (524).
Push the shaft protection sleeve and the lock washer
(931) onto the pump shaft.
Screw the impeller nut (922) onto the pump shaft.
Set the impellers in accordance with adjustment di-
mension L by turning the impeller nuts.
Following the setting process, fasten the impeller nuts
and secure them with the lock washers.
4.
Installation of stage casing and pump shaft
Horizontally clamp the discharge casing (107) (inter
casing on top).
VU 500/600/800/1200/1600
Insert the complete pump shaft (drive side point-
ing up) into the discharge casing (107), put down
on inter casing (137.3).
Force the stage casing (110) into the inter casing
(137.3).
VH 500/600/800/1200/1600
Force the stage casing (110.1) into the inter cas-
ing (137.3).
Insert the complete pump shaft (drive side point-
ing up) into the discharge casing (107).
Adjust the inter casings (137.2/137.1) (markings),
force them onto the stage casing (110.1) and put
them down.
Force the stage casing (110) into the inter casing
(137.1).