![Speck pumpen VH 110 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/speck-pumpen/vh-110/vh-110_operating-instructions-manual_1341817028.webp)
Operating Instructions
28
1096.0799 | VU / VH Series
10/2010
3.
Installation of stage casing and pump shaft
Horizontally clamp the discharge casing (107) (inter
casing on top).
VU 80/140/220
Insert the complete pump shaft (drive side point-
ing up) into the discharge casing (107), put it
down on inter casing (137.3).
Force the stage casing (110) into the inter casing
(137.3).
VH 110/140/180
Adjust the stage casing (110.1) (marks) and force
it into the inter casing (137.3).
Insert the complete pump shaft (211, drive side
pointing up) into the discharge casing (107).
Adjust the inter casings (marks), put them down
on the stage casing (110.1).
Force the stage casing (110) into the inter casing
(137.1).
4.
Installation of suction casing
Adjust the suction casing (106) (marks) and force it
onto the stage casing (110).
Secure the casing bolts (563) and slightly fasten them
with hexagon nuts (920.1).
5.
Installation of mechanical seal (drive side)
Moisten the auxiliary seal of the rotating unit (047) with
lubricant (grease containing PTFE).
Push the rotating unit (047) onto the pump shaft (211)
by a screwing movement in the sense of winding of the
spring.
Moisten the auxiliary seal of the stationary unit with lu-
bricant (alcohol, water).
Manually press the stationary unit (047) into the shaft
sealing casing (411).
Adjust the shaft sealing casing (441) (observe the
flushing channel), force it into the suction casing (106)
and fasten it to the suction casing (106) by means of
hexagon head screws (901.1).
6.
Installation of bearing housing on suction casing (drive
side)
Force the bearing cover (360.2) into the bearing hous-
ing (330) and adjust it, fasten it with hexagon head
screws (901.1).
Push the bearing housing (330) over the pump shaft
(211), force it into the suction casing (106) and fasten it
with hexagon head screws (901.1).
Press the rolling bearing (320) onto the pump shaft
(211).
Force the bearing cover (360) into the bearing housing
(330), adjust it and fasten it with hexagon head screws
(901.2).
Insert the fitting key (940) into the pump shaft.
7.
Installation of mechanical seal (non-drive side)
Rotate the pump 180° (drive side pointing down).
Moisten the auxiliary seal of the rotating unit (047.1)
with lubricant (grease containing PTFE).
Push the rotating unit (047.1) onto the pump shaft
(211) by a screwing movement in the sense of winding
of the spring.
Moisten the auxiliary seal of the stationary unit with lu-
bricant (alcohol, water).
Manually push the stationary unit (047.1) into the shaft
sealing casing (411).
Adjust the shaft sealing casing (441) (observe the
flushing channel), force it into the discharge casing
(107) and fasten it to the discharge casing (106) with
hexagon head screws (901.1).
8.
Installation of bearing housing on discharge casing (non-
drive side)
Force the bearing cover (360.2) into the bearing hous-
ing (330) and adjust it, fasten it with hexagon head
screws (901.1).
Force the bearing housing (330) into the discharge
casing (107) and fasten it with hexagon head screws
(901.1).
Press the rolling bearing (320) onto the pump shaft
(211).
Push the lock washer (931.1) onto the pump shaft.
Screw the shaft nut (921) onto the pump shaft, fasten
and secure with lock washer (931.1).
Force the bearing cover (360.1) into the bearing hous-
ing (330), adjust it and slightly fasten it with hexagon
head screws (901.1).
9. Pump
adjustment
Rotate the pump 90° (horizontal position).
Adjust the pump on level ground.
Tighten the casing bolts (563) and hexagon nuts
(920.1) crosswise.
10. Setting impeller position (non-drive side)
Loosen the hexagon head screws (901.1) on the bear-
ing cover (360.2).
Fasten the hexagon head screws (901.1) on the bear-
ing cover (360.1) until the impeller is in contact with the
inter casing (suction casing).
Start the gauge at the front (drive side) of the pump
shaft.
Loosen the hexagon head screws (901.1) on the bear-
ing cover (360.1).
Fasten the hexagon head screws (901.1) on the bear-
ing cover (360.2) until the impeller is in contact with the
inter casing (discharge casing).
Halve the determined measure X and adjust the pump
shaft/impeller by half the measure X (towards drive
side).
Fasten the pump shaft/impeller in this position by
evenly tightening the hexagon head screws (901.1) on
the bearing covers (360.1/360.2).
Verify unobstructed movement of the pump. Manually
rotate the pump shaft.
11. Pipe
installation
Not applicable to VU 80/VH 110
Put the seals (400) and pipes (700) onto the suc-
tion/the discharge flange, fasten with hexagon
head screws (901) and hexagon nuts (920).
7.5.12 Assembly of VU 300/450, VH 300/350/400
Cross-sectional drawing VU 300/450
Cross-sectional drawing, page 57
Cross-sectional drawing VH 300/350/400
Cross-sectional drawing, page 60
1.
Installation of valve flaps
Not applicable to VH 300/350/400
VU 450 inter casing (137/137.3)
VU 300 inter casing (137.3)
Put the stop plate (598/598.1) and the flap valve (746)
onto the inter casings (137/137.1).
Screw the hexagon head screws (901.5) with the
screw locking into the inter casings (137/137.3).