61
ERROR MESSAGES
Error:
Invalid parameters.
Error:
Config pointer out of range.
Error:
ENSONIQ AudioPCI™ tag not found.
Any of these three errors can occur if a user invokes APCONFIG.EXE
directly with arguments that are invalid. If the user is going to in-
voke this program (in order to view the AudioPCI™ hardware and
legacy settings), no arguments (parameters) should be entered on
the command line.
Error:
SNDSCAPE environment variable not found.
This will occur if the SNDSCAPE environment variable is not set in
the AUTOEXEC.BAT file. Make sure the “Enable Legacy Emula-
tion” box is checked on the Settings tab of the AudioPCI™ Device
Properties window.
Error:
Cannot read config file, SNDSCAPE.INI.
This will occur if the SNDSCAPE.INI file, pointed to by the
SNDSCAPE environment variable, cannot be found. Download and
install the latest AudioPCI™ drivers.
Error:
Config file is incomplete.
SNDSCAPE.INI entries are missing. This message is followed by
the name of the missing entry, i.e. SBPort. Download and install the
latest AudioPCI™ drivers.
Error:
Config contains an invalid value.
SNDSCAPE.INI entry has a bad value. This message is followed by
the name of the missing entry and its value, i.e. SBPort 592 (250
HEX). Download and install the latest AudioPCI™ drivers.
APCONFIG.EXE
Error:
PCI BIOS detect failed; <PCI BIOS-specific error message>.
Error:
PCI device detect failed; <PCI BIOS-specific error message>.
These will occur if a PCI BIOS was not detected or if the PCI BIOS
cannot locate our card in the system. They are both followed by PCI
BIOS-specific error messages, which are described starting on page
64.