54
SoundExpression
Reg.
Range Units
Default
Definition
S0
0-255
rings
0
Auto-answer
S1
0-255
rings
0
Count incoming rings
S2
0-255
rings
43
Escape character value.
S3
0-127
ASCII
13
Carriage return character.
S4
0-127
ASCII
10
Line feed character.
S5
0-255
ASCII
8
Backspace character.
S6
2-255
seconds
2
Wait time for Blind Dialing.
S7
1-255
seconds
50
Wait for carrier after dial.
S8
0-255
seconds
2
Pause time for dial delay.
S9
1-255
seconds
6 (0.6)
Carrier detect.
S10
1-255
seconds
14 (1.4)
Lost Carrier to Hang Up Delay.
S11
50-255 ms
95 ms
DTMF tone duration (* in one-hundredth second
increments)
S12
0-255
seconds
50(1)
Escape code guard time*. (*in one-fiftieth second
increments)
S13
Reserved.
S14
Bit Mapped
138(8Ah)
Bit mapped registers.
S15
Reserved
S16
Bit Mapped
0
Modem test options.
S17
Reserved.
S18
0-255
seconds
0
Test timer.
S19
Reserved.
S20
Reserved.
S21
Bit Mapped
4(04h)
Bit mapped registers.
S22
Bit Mapped
117(75h)
Bit mapped registers.
S23
Bit Mapped
54(36h)
Bit mapped registers.
S24
0-255
seconds
0
Sleep Inactivity Timer.
S25
0-255
seconds
5
Asynchronous DTR Delay.
S26
0-255
seconds
1
RTS to CTS Delay Interval.
S27
Bit Mapped
9(09h)
Bit mapped registers.
S28
Bit Mapped
0
Bit mapped registers
S29
0-255
ms
0
Flash Dial Modifier Time.
S30
0-255
tens of
0
Disconnect Inactivity Timer.
seconds
S31
Bit Mapped
2
S32
0-255
ASCII
17(11h)
XON Character.
Содержание SE14SRS