147
Specifications
A
ppe
ndix
Error messages
Error codes appear in the status display area when an error
(usually a hardware problem) occurs. In addition, both
error messages and error codes appear on the video
monitor screen or on a PC monitor connected to the
MONITOR connector.
When an error message appears, follow the instructions in
the error message to resolve the problem.
Specifications
General
External dimensions (w/h/d, excluding projections)
424 × 132 × 460 mm (16
3
/
4
× 5
1
/
4
×
18
1
/
8
inches)
Mass
XDS-PD1000: 17 kg (37 lb. 7.7 oz.)
XDS-PD2000: 16 kg (35 lb. 4.4 oz.)
Power requirements
90 V to 264 V AC, 47 Hz to 63 Hz
Power consumption
XDS-PD1000: 190 W
XDS-PD2000: 210 W
Inrush current
(1) Maximum possible inrush current at
initial switch-on (Voltage changes
caused by manual switching): 32 A
peak, 7 A r.m.s. (240 V AC)
(2) Inrush current after a mains
interruption of five seconds (Voltage
changes caused at zero-crossing):
13 A peak, 5 A r.m.s. (240 V AC)
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Storage temperature
–20ºC to +60ºC (–4ºF to +140ºF)
Operating relative humidity
20% to 90%
Error code
Example error code in status display area
Error code
Example error message in video monitor
in mm (inches)