128
Maintenance Menu
Chapt
er
7
Men
u
s
Maintenance Menu
Items in the maintenance menu
The following tables show the items in the maintenance
menu.
• The values in the “Setting” column are the values that
appear in settings screens. The values in brackets [ ] are
the value shown in menu screens (when they differ from
the values shown in settings screens).
• The underlined values are the factory defaults.
Refer to the Maintenance Manual for information about
menu item M1: ADJUST and about M2: SERVICE
SUPPORT settings not covered here.
a)
When the optional XDBK-106 is installed.
M2: SERVICE SUPPORT: Items related to service support
Item
Setting
M22: OPTION
SETTING
Set option installation states.
REDUNDANT PSU
Set whether to install the optional XDBK-101 and make power supply redundant.
ON:
Make redundant.
OFF:
Do not make redundant.
DVB-ASI I/O
Specify whether to install the optional PDBK-202.
on:
Install.
off:
Do not install.
AI422/AI420
a)
Select whether to enable AI422/AI420 format and limit the number of sessions to
five, or to disable AI422/AI420 and increase the number of sessions to eight.
disable [dis]:
Disable AI422/AI420 format and increase number of sessions to
eight.
enable [ena]:
Enable AI422/AI420 format and limit the number of sessions to
five.
M3: OTHERS: Other setting items
Item
Setting
M30: SOFTWARE VERSION
Display of the software version of this unit.
M31: SERIAL NUMBER
Display of the serial number and Media Access Control (MAC) address of this
unit.
M33: FILE I/F CONFIG
Select the directory structure to be displayed on the side of the computer when
this unit is accessed through FTP/CIFS connections.
FOLDER STYLE
xdcam style [xdcam]:
A structure matching with existing XDCAM devices
xds
style [xds]:
A structure supporting multiple media
M36: HOURS METER RESET
Reset the display of resettable items of the operating hours meter.
H11: OPE HOURS
H13: SEEK HOURS0
H14: SPDL HOURS
H15: LOAD COUNT
PD2000