75
Chapter 8 SCSI Commands
10
Autoloader
Temperature Limits
C
General environmental conditions inside the
autoloader are outside the specified temperature
range.
The autoloader supports this flag.
Autoloader temperature limits
exceeded.
11
Autoloader Voltage
Limits
C
The voltage supply to the autoloader is outside
the specified range. There is a potential problem
with the power supply or failure of a redundant
power supply.
The autoloader does not support this flag.
Autoloader voltage limits exceeded.
12
Autoloader Stray Tape
C
A cartridge has been left in a drive inside the
autoloader by a previous hardware fault:
1.Insert an empty magazine to clear the fault.
2.If the fault does not clear, turn the autoloader
off and then on again.
3.If the problem persists, call the customer
service.
The autoloader does not support this flag.
Stray cartridge left in autoloader after
previous |error recovery
13
Autoloader Pick Retry
W
There is a potential problem with a drive ejecting
cartridges short or with the autoloader
mechanism picking a cartridge from a slot.
1.No action needs to be taken at this time.
2.If the problem persists, call the customer
service.
The autoloader does not support this flag.
Operating to pick a cartridge from a
slot had to perform an excessive
number of retries before succeeding
14
Autoloader Place Retry
W
There is a potential problem with the autoloader
mechanism placing a cartridge into a slot.
1.No action needs to be taken at this time.
2.If the problem persists, call the customer
service.
The autoloader does not support this flag.
Operation to place a cartridge into a
slot had to perform an excessive
number of retries before succeeding
15
Autoloader Load Retry
W
There is a potential problem with a drive or
autoloader mechanism loading cartridges, or an
incompatible cartridge.
The autoloader does not support this flag.
Operation to load a cartridge into a
drive had to perform an excessive
number of retries before succeeding
16
Autoloader door
C
The operation has failed because the autoloader
door is open:
1.Clear any obstructions from the autoloader
door.
2.Close the autoloader door.
3.If the problem persists, call the customer
service.
Changer door open prevents
autoloader functioning.
17
Autoloader Mailslot
C
There is a mechanical problem with the
autoloader media import/export mailslot.
The autoloader does not support this flag.
Mechanical problem with import/
export mailslot
18
Autoloader Magazine
C
The autoloader cannot operate without the
magazine
1.Insert the magazine into the autoloader.
2.Restart the operation.
The autoloader does not support this flag.
Autoloader magazine not present
19
Autoloader Security
W
Autoloader security has been compromised.
door is open.
The autoloader does not support this flag.
Autoloader door opened then closed
during operation
20
Autoloader Security
Mode
I
The security mode of the autoloader has been
changed.
The autoloader has either been put into secure
mode, or the autoloader has exited the secure
mode.
This is for information purposes only. No action
is required.
The autoloader does not support this flag.
Autoloader security mode changed.
No.
Flag
Type Required Host Message
Cause