147
Appendix
A.10. Error Code List
When the AIT autoloader generates an error, an error code appears on the
message display. The following is the list of error codes that can appear on the
message display. If a message from the list appears on the message display,
contact customer service.
If an error code appears on the message display that does not figure in this list,
before contacting customer service verify the LED on the front of the AIT
autoloader, as well as perform the operations outlined in “Other Messages”
(page 151)
If the problem persists, contact customer service.
Error code Description
Display
Logged
00
No valid error code
information.
—
No
01
Detected a microcode
anomaly upon startup.
[0 1] appears on the
message display.
No
02
Detected a base RAM
anomaly upon startup.
[0 2] appears on the
message display.
No
03
Detected a buffer RAM
anomaly upon startup.
[L ] and [0 3] appear
alternately on the message
display.
No
20
The Identify message
detected a SCSI parity error
after selection.
—
Yes
21
Detected SCSI parity error.
Message Out phase retried
but gave up.
—
Yes
22
Detected SCSI parity error.
Command phase retried but
gave up.
—
Yes
23
Detected SCSI parity error.
Data Out phase retried but
gave up.
—
Yes
24
Detected a parity error
message. Message In phase
retried but gave up.
—
Yes
25
Received Initiator detected
error message. Message
phase retried but gave up.
—
Yes
26
Received Initiator detected
error message. Command
phase retried but gave up.
—
Yes
27
Received Initiator detected
error message. Status phase
retried but gave up.
—
Yes
28
Received Initiator detected
error message. Data In phase
retried but gave up.
—
Yes
29
Received Initiator detected
error message. Data Out
phase retried but gave up.
—
Yes
2A
Received an illegal message
from the SCSI interface.
—
Yes
2B
Received an illegal Identify
message at the SCSI interface
—
Yes